The I/O module is the heart of the FCS system. It connects all sensors and actuators and manages all data input and output. It also supplies power to all devices.
Equipped with 14 connectors, an LED, and advanced electronics, the I/O module offers great flexibility and functionality.
Control is handled via the FCS display module.
| Cod. | 6119855 |
|---|
Inputs/outputs:
Power: 24V DC, 2A max – LP12 2-pin
Display module connection: CAN bus + 24V – LP12 6-pin
External relay module, control signal 0–5V / 4–20mA + current measurement – LP12 7-pin
4 relay outputs with current measurement, 1 reversible voltage – LP12 2-pin
4 CAN + 24V outputs with current measurement – LP12 5-pin
1 CAN extension – LP12 5-pin
2 PT1000 temperature sensor inputs – LP12 3-pin
Installation:
4 screw holes with 5 mm diameter. Designed for countersunk screws.